0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DEL-LY4F- DC24

DEL-LY4F- DC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON - DEL-LY4F- DC24 - RELAY, 4PDT, 240VAC, 30VDC, 10A

  • 数据手册
  • 价格&库存
DEL-LY4F- DC24 数据手册
Bi-power Relays LY CSM_LY_DS_E_4_5 Power-switching Compact General-purpose Relays • The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and Material Safety Act. • Equipped with an arc barrier for arc interruption. • Withstand voltages up to 2,000 V. • New built-in diode and built-in CR circuit models have joined the series. • The lineup also includes models that are compliant with the LR and VDE safety standards. • Single-pole and double-pole models have AC4 ratings and DC2 ratings (operating coil ratings: 100/ 110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC, and 100/110 VDC). • Three-pole and four-pole models have AC4 ratings and DC2 ratings (operating coil ratings: 100/110 VAC, 200/220 VAC and 100/110 VDC). Refer to the standards certifications and compliance section of your OMRON website for the latest information on certified models. Refer to the Common Relay Precautions. Model Number Structure Relays with Plug-in Terminals Relays with PCB Terminals Case-surface mounting Structure Classification Number of poles *LY1 **LY1N *LY1-0 *LY1F *LY2 **LY2N *LY2-0 *LY2F **LY2Z **LY2ZN **LY2Z-0 **LY2ZF 3 *LY3 **LY3N *LY3-0 *LY3F 4 *LY4 **LY4N *LY4-0 *LY4F 1 **LY1-D **LY1N-D2 --- --- **LY2-D **LY2N-D2 --- --- **LY2Z-D **LY2ZN-D2 --- --- 3 **LY3-D **LY3N-D2 --- --- 4 **LY4-D **LY4N-D2 --- --- 1 --- --- **LY2-CR **LY2N-CR **LY2Z-CR **LY2ZN-CR 1 Standard models Compliance with Electrical Appliances and Material Safety Act Models with diode for coil surge absorption (DC coil specification only) Models with CR circuits for coil surge absorption (AC coil specification only) With operation indicators 2 2 2 Bifurcated Bifurcated Bifurcated Note: 1. Cells with a diagonal line cannot be manufactured. Ask your OMRON representative for details on manufacturing products for cells containing “---” in the above table. 2. If #187 tab terminals are required, use the LY1F-T2 or LY2F-T2 (single-pole or double-pole models only). 3. Refer to page 12 for information on plug-in terminal and socket combinations. 4. Items with an asterisk (*) in the table are certified for UL, CSA, and SEV. This is indicated with a certification mark on the products. 5. Items with two asterisks (**) in the table are certified for UL and CSA. This is indicated with a certification mark on the products. 6. All models in the table are certified for IEC (TÜV). 7. The models with plug-in terminals (single-pole, double-pole, and 4-pole) were combined with the PTF-E for the EC Declaration of Conformity. These products display the CE Marking. 1 LY Ordering Information When your order, specify the rated voltage. Models with Plug-in Terminals Number of poles Classification Model Standard models Models with built-in operation indicators Models with single Models with built-in contacts diodes Models with built-in diodes and operation indicators LY1 LY1N LY1-D 1 pole Rated voltage (V) 12, 24, 100/110, 110/120, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 100/110, 110/120, or 200/220 VAC 12, 24, or 100/110 VDC 12, 24, 48, or 100/110 VDC Model LY2 LY2N LY2-D LY1ND2 12, 24, or 48 VDC LY2N-D2 Models with built-in CR circuits --- --- LY2-CR Models with built-in CR circuits and operation indicators --- --- LY2N-CR --- --- Standard models Models with built-in operation indicators Bifurcated contacts Models with built-in diodes Models with built-in diodes and operation indicators Models with built-in CR circuits Models with built-in CR circuits and operation indicators LY2Z 2 poles Rated voltage (V) 12, 24, 100/110,110/ 120, 200/220, or220/240 VAC 12, 24, 48, or 100/110 VDC 12, 24, 100/110,110/ 120, 200/220, or 220/240 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC Model LY3 LY3N LY3-D 12, 24, 48, or 100/110 VDC LY3ND2 100/110, 110/120, 200/220, or 220/240 VAC 100/110, 110/120, 200/220, or 220/240 VAC 100/110 or200/220 VAC 12, 24, 48, or 100/ 110 VDC 100/110, 110/120, 200/220, or 220/240 VAC 12 or 24 VDC 3 poles Rated voltage (V) 12, 24, 100/110, or 200/220 VAC Model LY4 4 poles Rated voltage (V) 12, 24, 100/110, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC 12, 24, 100/110, or 200/220 VAC 12, 24, 100/110, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC 12, 24, or 100/110 VDC LY4N LY4-D LY4ND2 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- LY2Z-D 12, 24, or 48 VDC --- --- --- --- --- --- LY2ZND2 12, 24, or 100/110 VDC --- --- --- --- --- --- LY2Z-CR 100/110 VAC --- --- --- --- --- --- LY2ZNCR 100, 110, 110/1 20, or 200/220 VAC --- --- --- --- LY2ZN Relays with PCB Terminals Number of poles Classification Model Models with single contacts LY1-0 1 pole Rated voltage (V) 24,100/110, 110/120, or 200/220 VAC Model LY2-0 12 or 24 VDC Bifurcated contacts --- --- LY2Z-0 2 poles Rated voltage (V) 12, 24, 100/110, 110/120, 200/ 220, or 220/240 VAC 12, 24, 48 or 100/110 VDC 100/110 VAC 24, 48, or 100/110 VDC Model LY3-0 3 poles Rated voltage (V) 24, 100/110, or 200/220 VAC Model LY4-0 12, 24, 48, or 100/110 VDC 4 poles Rated voltage (V) 24, 100/110, or 200/ 220 VAC 12, 24, 48, or 100/110 VDC --- --- --- --- Model 3 poles Rated voltage (V) Model --- Case-surface Mounting Number of poles Classification Models with single contacts Bifurcated contacts Model LY1F --- 1 pole Rated voltage (V) 24, 100/110, 110/120, 200/220, or 220/240 VAC 6, 12, 24, or 100/110 VDC --- Model LY2F LY2ZF 2 poles Rated voltage (V) 12, 24, 100/110, 110/ 120, 200/220, or 220/240 VAC 12, 24, 48, or 100/110 VDC 24, 100/110, or 200/220 VAC LY3F 12, 24, 100/110, or 200/220 VAC LY4F --- 12, 24, 100/110, or 200/220 VAC 12, 24, or 100/110 VDC 12, 24, or 100/110 VDC --- 4 poles Rated voltage (V) --- --- 12 or 24 VDC 2 LY Ratings and Specifications Ratings Standard Models with Built-in Operation Indicators Operating Coil, Single-pole and Double-pole Models Item Rated voltage (V) DC Coil inductance (H) Coil resistance (Ω) Armature OFF Must-operate voltage (V) Armature ON 50 Hz 60Hz 12 106.5 91 46 0.17 0.33 24 53.8 46 180 0.69 1.3 25.7 22 788 3.22 5.66 100/110 11.7/12.9 10/11 3,750 14.54 24.6 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 50 AC Rated current (mA) 200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 6 150 40 0.16 0.33 12 75 160 0.73 1.37 24 36.9 650 3.2 5.72 18.5 2,600 10.6 21.0 9.1/10 11,000 45.6 86.2 Rated current (mA) Armature OFF 48 100/110 Must-release voltage (V) Maximum voltage (V) Power consumption (VA, W) Approx. 1.0 to 1.2 (at 60 Hz) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Approx. 0.9 to 1.1 (at 60 Hz) Approx. 0.9 3 poles Item Coil inductance (H) 50 Hz 60Hz Coil resistance (Ω) 12 159 134 24 0.12 0.21 24 80 67 100 0.44 0.79 100/110 14.1/16 12.4/13.7 2,300 10.5 18.5 200/220 9.0/10.0 7.7/8.5 8,650 34.8 59.5 Rated voltage (V) AC Must-operate voltage (V) Armature ON 12 112 107 0.45 0.98 24 58.6 410 1.89 3.87 48 28.2 1,700 8.53 13.9 12.7/13 8,500 29.6 54.3 Rated current (mA) Coil resistance (Ω) Armature OFF DC 100/110 Must-release voltage (V) Maximum voltage (V) Power consumption (VA, W) Approx. 1.6 to 2.0 (at 60 Hz) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Approx. 1.4 4 poles Item Rated voltage (V) Coil inductance (H) Must-operate voltage (V) Armature ON 50 Hz 60Hz 12 199 170 20 0.1 0.17 24 93.6 80 78 0.38 0.67 AC 100/110 22.5/25.5 19/21.8 1,800 10.5 17.3 200/220 11.5/13.1 9.8/11.2 6,700 33.1 57.9 12 120 100 0.39 0.84 24 69 350 1.41 2.91 48 30 1,600 6.39 13.6 15/15.9 6,900 32.0 63.7 DC 100/110 Must-release voltage (V) Maximum voltage (V) Power consumption (VA, W) Approx. 1.95 to 2.5 (at 60 Hz) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Approx. 1.5 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for the AC rated current and ±15% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only. (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum voltage capacity was measured at an ambient temperature of 23°C. *1. There is variation between products, but actual values are 80% max. To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C). *2. The actual values are 30% min. for AC and 10% min. for DC. To ensure release, use a value that is lower than the specified value. 3 LY Refer to List of Certified Models for a list of models that are certified for safety standards and the Electrical Appliances and Material Safety Act. Classification Item Load 1 pole Resistive load Contact type Contact materials 15 A at 110 VAC 15 A at 24 VDC Rated load Rated carry current Maximum contact voltage Maximum contact current 15 A Double-, 3-, and 4-pole models Inductive load Inductive load Resistive load (cos φ = 0.4, L/R = 7 ms) (cos φ = 0.4, L/R = 7 ms) Single Ag alloy 10 A at 110 VAC 10 A at 110 VAC 7.5 A at 110 VAC 7 A at 24 VDC 10 A at 24 VDC 5 A at 24 VDC 15 A 10 A 250 VAC 250 VAC 125 VDC 125 VDC 15 A 10 A 10 A Type Single-pole and double-pole models (standard models and bifurcated contact models) Item Single-pole, double-pole models (models with built-in operation indicators, models with built-in diodes, and models with built-in CR circuits), 3-pole and 4-pole models −25 to 55°C (with no icing or condensation)*1 Ambient operating temperature Ambient operating humidity −25 to +40°C (with no icing or condensation)*2 5% to 85% Note: Bifurcated contacts Inductive load (cos φ = 0.4, L/R = 7 ms) Bifurcated Ag 5 A at 110 VAC 4 A at 110 VAC 5 A at 24 VDC 4 A at 24 VDC 7A 250 VAC 125 VDC 7A 7A Resistive load 1. Some models in the LY1 and LY2 Series have an upper temperature limit of +40°C. This limitation is due to the diode junction temperature and the elements used. 2. Refer to the ambient temperature and contact carry current characteristics data on page 5 to 7 for information on operation in temperature conditions that are not described here. 3. When you apply a minimum of 10 A of current to an LY1 when it is used in combination with a PTF08A, PTF08AE, or PT08, connect each of the following terminal pairs: (1) to (2), (3) to (4), and (5) to (6). *1. If the carry current is 4 A or less, the usable ambient temperature range is −25 to 70° C. *2. If the flowing current is 4 A or less, the usable ambient temperature range is -25 to 55° C. Characteristics Type Item Contact resistance*1 Operating time*2 Release time*2 Maximum Mechanical operating Rated load frequency Insulation resistance*3 Between coil and contacts Between contacts of Dielectric different polarity strength Between contacts of the same polarity Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Endurance Electrical*4 Failure rate P value (reference value)*5 Weight Standard models, models with built-in operation indicators, models with built-in CR circuits, and models with built-in diodes 50 mΩ max. 25 ms max. 25 ms max. 18,000 operations/h Bifurcated contacts Note: The values at the left are initial values. *1. Measurement conditions: 1 A at 5 VDC using the voltage drop method *2. Measurement conditions: With rated operating power applied, not including contact bounce. Ambient temperature condition: 23° C *3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement. *4. Ambient temperature condition: 23° C *5. This value was measured at a switching frequency of 120 operations per minute. 1,800 operations/h 100 MΩ min. 2,000 VAC at 50/60 Hz for 1 min. 1,000 VAC at 50/60 Hz for 1 min. 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) 1,000 m/s2 200 m/s2 AC: 50,000,000 operations min. (switching frequency: 18,000 DC: 100,000,000 operations min. operations/h) 1-, 3-, 4-pole: 200,000 operations min. 2-pole: 500,000 operations min. 2-pole: 500,000 operations min. (rated load, operating frequency: 1,800 (rated load, operating frequency: 1,800 operations/h) operations/h) 100 mA at 5 VDC 10mA at 5 VDC 1-pole and 2-pole: 40 g, 3-pole: Approx. 50 g, 4-pole: Approx. 70 g Endurance Under Real Loads (Reference Only) Item Load type AC motor AC lamp Capacitor (2,000 µF) AC solenoid LY1, 100 VAC Conditions Operating frequency LY2, 100 VAC Electrical life (×10,000 operations min.) 400 W, 100 VAC singlephase with 35-A inrush ON for 10 s, current, 7-A current OFF for 50 s flow 5 300 W, 100 VAC with 51-A inrush current, 3A current flow 10 500 W, 100 VAC with 78-A inrush current, 5A current flow 24 VDC with 50-A inrush current, 1-A current flow 50 VA with 2.5-A inrush current, 0.25-A current flow 100 VA with 5-A inrush current, 0.5-A current flow ON for 5 s, OFF for 55 s 2.5 ON for 1 s, OFF for 6 s 10 150 ON for 1 s, OFF for 2 s 80 Conditions Operating frequency LY4, 100 VAC Electrical life (×10,000 operations min.) Conditions 200 W, 200 VAC threephase with 5-A inrush current, 1-A current flow Operating frequency Electrical life (×10,000 operations min.) 50 200 W, 100 VAC singlephase with 25-A inrush ON for 10 s, current, 5-A current OFF for 50 s flow 20 300 W, 100 VAC with 51-A inrush current, 3A current flow 8 300 W, 100 VAC with 51-A inrush current, 3A current flow ON for 5 s, OFF for 55 s 5 1 24 VDC with 50-A inrush current, 1-A current flow ON for 1 s, OFF for 15 s 0.5 15 24 VDC with 20-A inrush current, 1-A current flow ON for 1 s, OFF for 2 s 20 100 50 VA with 2.5-A inrush current, 0.25-A current flow 24 VDC with 50-A inrush current, 1-A current flow 24 VDC with 20-A inrush current, 1-A current flow 50 VA with 2.5-A inrush current, 0.25-A current flow 100 VA with 5-A inrush current, 0.5-A current flow ON for 5 s, OFF for 55 s ON for 1 s, OFF for 15 s ON for 1 s, OFF for 2 s 50 750 W, 200 VAC threephase with 18-A inrush current, 3.5-A current flow 100 VA with 5-A inrush current, 0.5-A current flow ON for 10 s, OFF for 50 s 7 100 ON for 1 s, OFF for 2 s 50 4 LY Engineering Data Engineering Data Maximum Switching Capacity AC resistive load 15 10 5 Life: 200,000 operations AC inductive load (cos φ = 0.4) 1 LY3 and LY4 AC resistive load 10 5 AC inductive load (cos φ = 0.4) 1 DC inductive load (L/R = 7 ms) Life: 500,000 operations Contact current (A) LY2 Contact current (A) Contact current (A) LY1 DC resistive load 0.1 0.1 50 DC inductive load (L/R = 7 ms) DC resistive load 0.1 10 AC inductive load (cos φ = 0.4) 0.5 DC resistive load 0 5 Life: 200,000 operations 5 1 DC inductive load (L/R = 7 ms) 0.5 0.5 AC resistive load 10 100 500 1,000 0 5 10 50 100 500 Contact voltage (V) 0 5 1,000 10 50 100 500 1,000 Contact voltage (V) Contact voltage (V) Endurance Curve AC resistive load 10 AC inductive load (cos φ = 0.4) 5 DC resistive load 1 0.5 DC inductive load (L/R = 7 ms) LY2 Number of operations (×104 operations) LY1 Number of operations (×104 operations) Contact current (A) LY2Z 1,000 110 VAC resistive load 500 24 VDC resistive load 100 50 1,000 24 VDC resistive load 500 110 VAC resistive load 100 50 110 VAC inductive load (cos φ = 0.4) 24 VDC inductive load (L/R = 7 ms) 0.1 Life: 500,000 operations 0 5 10 50 24 VDC 110 VAC inductive load inductive load (cos φ = 0.4) (L/R = 7 ms) 10 100 500 1,000 0 2 4 6 8 10 12 Contact voltage (V) 10 0 14 16 18 20 Switching current (A) 2 4 6 8 10 12 14 16 18 20 Switching current (A) Ambient Temperature vs. Mustoperate and Must-release Voltage 1,000 24 VDC resistive load 500 110 VAC resistive load 100 110 VAC inductive load (cos φ = 0.4) 50 LY2 100/110 VAC at 50Hz Must-operate/must-release voltage (%) LY2Z Number of operations (×104 operations) Number of operations (×104 operations) LY3 and LY4 1,000 24 VDC resistive load 110 VAC resistive load 110 VAC inductive load (cos φ = 0.4) 500 100 50 24 VDC inductive load (L/R = 7 ms) 24 VDC inductive load (L/R = 7 ms) 10 0 2 4 6 8 100 Number of Relays: 5 Must-operate voltage Must-release voltage (average value) 80 60 40 20 10 10 12 0 14 16 18 20 Switching current (A) 2 4 6 8 10 0 −40 −20 0 20 Switching current (A) 40 60 80 Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise Must-operate voltage Must-release voltage Number of Relays: 5 (average value) 80 60 120 Rating: 100% applied 110 Rated power consumption: 1 W 100 90 80 70 60 50 40 LY1 100/110 VAC at 50Hz Maximum operating temperature (120° C) 15 A 10 A Coil temperature rise (°C) 100 LY1 24 VDC Coil temperature rise (°C) Must-operate/must-release voltage (%) LY2 24 VDC 120 90 80 70 50 40 40 No contact current 20 30 30 20 20 −40 −20 0 20 40 60 80 Ambient temperature (°C) 0 Maximum operating temperature (120° C) 15 A 10 A 7A 5A 3A No contact current 10 10 0 Rated power consumption: 1 VA 100 60 7A 5A 3A Rating: 100% applied 110 10 20 30 40 50 60 70 80 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 5 LY Rating: 100% applied Rated power consumption: 1 W 110 100 Maximum operating temperature (120° C) 90 80 10 A 70 120 Rating: 100% applied Rated power consumption: 1.0 VA 110 100 Maximum operating temperature (120° C) 90 80 70 10 A 7A 5A 3A 7A 50 50 5A 3A 40 40 100 90 Maximum operating temperature (120° C) 10 A 80 70 50 7A 5A 3A 40 20 10 10 20 30 40 LY3 100/110 VAC at 50Hz Rating: 100% applied Rated power consumption: 1.6 VA 100 10 A 90 10 10 20 30 40 50 60 70 80 Ambient temperature (°C) LY4 24 VDC 120 110 30 20 0 50 60 70 80 Ambient temperature (°C) Maximum operating temperature (120° C) 80 Coil temperature rise (°C) 10 No contact current Rating: 100% applied Rated power consumption: 1.5 W 110 100 7A 70 7A 60 5A 60 5A 50 3A 50 3A No contact current Maximum operating temperature (120° C) 10 A 80 70 40 90 70 60 50 40 No contact current 30 20 10 10 40 50 60 70 80 50 60 70 80 Ambient temperature (°C) Maximum operating temperature (120° C) 10 A 80 20 30 40 Rating: 100% applied Rated power consumption: 1.95 VA 110 30 20 30 100 20 10 20 120 30 0 10 LY4 100/110 VAC at 50Hz 120 90 0 Coil temperature rise (°C) 30 No contact current 0 Coil temperature rise (°C) Rating: 100% applied Rated power consumption: 1.4 VA 110 No contact current 20 40 120 60 60 60 30 LY3 24 VDC Coil temperature rise (°C) LY2 100/110 VAC at 50Hz 120 Coil temperature rise (°C) Coil temperature rise (°C) LY2 24 VDC 7A 5A 3A No contact current 10 10 0 20 30 40 Ambient temperature (°C) 50 60 70 80 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) Models with built-in diodes The diode absorbs surge from the coil. With Diode Without Diode ON OFF ON OFF 140 V A 24 VDC Di To digital memory A 24 VDC A’ To digital memory A’ Note: 1. Make sure that the polarity is correct. 2. The release time will increase, but the 25-ms specification for standard models is satisfied. 3. Diode characteristics: Reversed dielectric strength: 1,000 V Forward current: 1 A Models with Built-in CR Circuits With CR Without CR 282 V 2.5 msec ms 282 V 80 V 9.4 ms 4.12 ms 600 V A 200 AC C = 0.033 μF R = 120 Ω A’ 200 AC A To digital memory scope A’ 6 LY Malfunctioning Shock LY2 100/110 VAC Y 560 N = 20 Measurement: Shock was applied 2 times each in 6 directions along 3 axes with the Relay energized and not energized to check the shock values that cause the Relay to malfunction. Criteria: Non-energized: 200 m/s2 , Energized: 200 m/s2 Energized Not energized 440 X 720 500 520 Z 370 Shock direction 350 450 520 700 Z' X X' X' Y Z 500 Y' Unit: m/s2 600 Z' Y' Dimensions (Unit: mm) Solder terminals LY1 LY1N LY1-D LY1N-D2 Terminal Arrangement/Internal Connections (Bottom View) LY1 LY1N-D 0.5 Eight, 2-dia. holes 28 max. (The coil has no polarity.) 5 36 max. (Check the coil polarity when wiring and wire all connections correctly.) 21.5 max. 3 6.4 LY1N DC Models Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY2 LY2Z LY2N LY2ZN LY2-D LY2Z-D LY2N-D2 LY2ZN-D2 LY1N-D2 AC Models Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. Terminal Arrangement/Internal Connections (Bottom View) LY2(Z) LY2(Z)-D (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. 0.5 Eight, 3-dia. holes 36 max. 3 6.4 LY2(Z)N 28 max. DC Models 5 AC Models LY2(Z)N-D2 21.5 max. Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. 7 LY LY3 LY3N LY3-D LY3 Terminal Arrangement/Internal Connections (Bottom View) LY3-D 0.5 28 max. (The coil has no polarity.) 5 36.5 max. 3 6.4 Check the coil polarity when wiring and wire all connections correctly. 31.5 max. Eleven, 3-dia. holes LY3N DC Models Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY4 LY4N LY4-D LY4N-D2 AC Models Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Terminal Arrangement/Internal Connections (Bottom View) LY4 LY4-D 0.5 28 max. (The coil has no polarity.) 5 36 max. 3 6.4 Check the coil polarity when wiring and wire all connections correctly. 41.5 max. Fourteen, 3-dia. holes LY4N-D2 LY4N DC Models AC Models Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY2-CR LY2Z-CR LY2N-CR LY2ZN-CR Terminal Arrangement/Internal Connections (Bottom View) LY2(Z)-CR LY2(Z)N-CR 0.5 Eight, 3-dia. holes* 28 max. 5 3 53 max. CR element C = 0.033 μF R = 120 Ω 21.5 max. 6.4 *These dimensions are for the LY2N-CR. (The coil has no polarity.) 8 LY Relays with PCB Terminals PCB Processing Dimensions (Bottom View) LY1-0, LY3-0, LY2-0, and LY4-0 1 pole 2 poles 3 poles 4 poles 28 max. 21.5 max. 36 max. Five, 2.5-dia. holes Note: The figures and dimensions depicted here are for the LY2-0. The dimension with an asterisk (*) is 6.4 for the LY1-0. Eight, 2.5-dia. holes Eleven, 2.5-dia. holes Fourteen, 2.5-dia. h Note: 1. The dimensional tolerance is 0.1 mm. 2. There are exposed parts (conductive parts) on the LY1-0 other than the terminals. Be careful when using this Relay on a double-sided PCBs. Terminal Arrangement/Internal Connections (Bottom View) LY1-0 LY2-0 LY3-0 LY4-0 2 3 6 7 8 (The coil has no polarity.) Case-surface mounting LY1F LY2F Mounting Hole Dimensions 22.5 max. Terminal Arrangement/Internal Connections (Bottom View) LY1F LY2F 44 max. 29 max. Two, 3.5-dia. holes or two M3 screw holes Eight, 2-dia. holes* 35.5 max. (The coil has no polarity.) Note: The dimensional tolerance is ±0.1 mm. Note: The figures and dimensions depicted here are for the LY1F. The LY2F is also conforms to these measurements. LY3F Mounting Hole Dimensions 32 max. Terminal Arrangement/Internal Connections (Bottom View) LY3F 28.5 max. 44 max. Two, 3.5 dia. holes or two M3 screw holes Eleven, 3-dia. holes (The coil has no polarity.) 36 max. LY4F Mounting Hole Dimensions 41.5 max. Terminal Arrangement/Internal Connections (Bottom View) LY4F Three, 3.5 dia. holes or two M3 screw holes 28 max. Fourteen, 3-dia. holes 44 max. (The coil has no polarity.) 35.5 max. 9 LY Details on Safety-standard-certified Models, LY@ • Standard models are certified for the UL, CSA, and SEV safety standards. • Refer to Model Number Structure on page 1 for a list of applicable models. • The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. UL-certified Models (File No. E41643) Model Coil ratings Number of poles Contact ratings 15A, 120VAC (General use) CSA-certified Models (File No. LR31928) Certified number of operations Model Coil ratings Number of poles 100,000 operations Contact ratings 15A, 120VAC (General use) 15A, 240VAC (General use) 6,000 operations 1 100,000 operations 15A, 240VAC (General use) 6,000 operations 15A, 30VDC (Resistive) 6 to 240VAC 6 to 125VDC Certified number of operations 15A, 30VDC (Resistive) 6 to 240VAC 6 to 125VDC 1/2HP, 120VAC 100,000 operations 1 1/2HP, 120VAC 100,000 operations 8.5FLA, 30LRA, 120VAC 8.5FLA, 30LRA, 120VAC TV-5, 120VAC 25,000 operations TV-5, 120VAC 25,000 operations 470VA, Pilot duty, 120VAC 6,000 operations 470VA, Pilot duty, 120VAC 6,000 operations 15A, 120VAC (General use) 100,000 operations 15A, 120VAC (General use) 12A, 240VAC (General use) 12A, 240VAC (General use) 7A, 250VAC (General use) 7A, 250VAC (General use) 6,000 operations 6,000 operations 15A, 30VDC (Resistive) 15A, 30VDC (Resistive) 5A, 38VDC (Resistive) LY 6 to 240VAC 6 to 125VDC 5A, 38VDC (Resistive) 1/2HP, 120VAC 100,000 operations 1/3HP, 240VAC 1,000 operations 2 LY 6 to 240VAC 6 to 125VDC 1/2HP, 120VAC 100,000 operations 1/3HP, 240VAC 1,000 operations 2 8.5FLA, 30LRA, 120VAC 8.5FLA, 30LRA, 120VAC 100,000 operations 100,000 operations 5FLA, 50LRA, 50VDC TV-3, 120VAC 5FLA, 50LRA, 50VDC 25,000 operations TV-3, 120VAC 345VA, Pilot duty, 120-240VAC 25,000 operations 345VA, Pilot duty, 120-240VAC 6,000 operations 6,000 operations B300/R300 B300/R300 Pilot duty 10A, 240VAC (General use) (Same polarity) 10A, 240VAC (General use) (Same polarity) 6,000 operations 10A, 30VDC (General use) (Same polarity) 6 to 240VAC 6 to 125VDC 3 4 10A, 30VDC (Resistive) (Same polarity) 6,000 operations 2A, 40VDC (Resistive) (Same polarity) 6 to 240VAC 6 to 125VDC 1/2HP, 240VAC 1,000 operations 0.6A, 100VDC (Resistive) (Same polarity) 6,000 operations 3 4 1/8HP, 240VAC (Same polarity) 1/2HP, 240VAC (Same polarity) 1,000 operations 1/3HP, 240VAC (Same polarity) 2A, 40VDC (Resistive) 6,000 operations 0.6A, 100VDC (Resistive) SEV-certified Models (File No. 11, 0573) TÜV-certified Models (File No. R50030064, EN 61810-1) Model Coil ratings Number of poles Contact ratings Model Certified number of operations Coil ratings Number of poles Contact ratings 15 A at 24 VDC 6 to 110 VDC 2 to 240 VAC 1 6 to 110 VDC 2 to 240 VAC 2 to 4 15 A at 220 VAC LY@ 15 A, 110 VDC resistive load 10 A, 110 VAC inductive load Certified number of operations 6,000 operations 10 A at 24 VDC 10 A at 220 VAC 10 A, 250 VAC resistive load 1 7A, 250 VAC inductive load 10 A, 30 VDC resistive load 7 A, 30 VDC inductive load LY@ 10 A, 110 VAC resistive load 6 to 240 VAC 6 to 110 VDC 200,000 operations 7.5A, 110 VAC inductive load 7A, 250 VAC resistive load 2 4 A, 250 VAC inductive load 7 A, 30 VDC resistive load 4 A, 30 VDC inductive load 3 4 10 A, 110 VAC resistive load 7.5A, 110 VAC inductive load 100,000 operations 10 LY • When ordering a model that is certified for VDE or Lloyd’s Register (LR) standards, always specify “VDE-certified Model” or “LR Standardcertified Model” with your order. VDE Certification (Certificate No. 6359, EN 61810-1) Model Coil ratings Number of poles Contact ratings Certified number of operations 10 A, 220 VAC resistive load 7 A, 220 VAC inductive load 1 10 A, 28 VDC resistive load LY@-VD 6, 12, 24, 50, 110, or 220 VAC 6, 12, 24, 48, or 110 VDC 7 A, 28 VDC inductive load 7 A, 220 VAC resistive load 200,000 operations 4 A, 220 VAC inductive load 2 7 A, 28 VDC resistive load 4 A, 28 VDC inductive load LR-certified Models (File No. 00/10047) Model LY@ Coil ratings 6 to 240 VAC 6 to 110 VDC Number of poles Contact ratings 2 7.5 A, 230 VAC inductive load 4 5 A, 24 VDC inductive load Compliance with Electrical Appliances and Material Safety Act All standard models comply with the Electrical Appliances and Material Safety Act. Model LY@ Coil ratings 6 to 240 VAC 6 to 120 VDC Number of poles Contact ratings 1 15 A at 200 VAC 2 3 4 10A at 200 VAC 11 LY Connection Sockets (Refer to Common Socket and Item Number of poles DIN Track Products for external dimensions.) The following front connector sockets are all Back-mounting Sockets individually certified for UL/CSA: PTF08A, PTF11A, and PTF14A. Front-mounting Sockets Track or screw mounting Solder terminals Wrapping terminals Relays with PCB Terminals 1 or 2 PTF08A(-E) PT08 PT08QN PT08-0 3 PTF11A PT11 PT11QN PT11-0 PTF14A(-E) PT14 PT14QN Model Standards PTF08A PTF11A PTF14A No. UL File No. E87929 CSA File No. LR31928 PT14-0 4 Note: The PTF@A-E Relays have finger protection. Round terminals cannot be used. Use forked terminals. and DIN Track Products for external dimensions.) Relay Hold-down Clips (Refer to Common Socket Used with Socket mounting plate Used with Socket PYC-A1 PYC-P PYC-S Y92H-3 Approx. 3 Number of poles Applicable Relay • • • • • Standard models: LY@ Bifurcated contact models: LY@Z Models with built-in operation indicators: LY@N Models with built-in diodes: LY@-D(2) Models with built-in CR circuits: LY@-CR 1 or 2 PTF08A PYC-1 Approx. 2.5 Application Table Connection Socket and Hold-down Clip Item For models with built-in CR circuits Front-mounting Sockets Back-mounting Sockets Track or screw mounting Solder terminals, wrapping terminals, or PCB terminals PTF11A PTF14A Applicable Hold-down Clips z PT08(QN) PT08-0 PT14(QN) PT14-0 z PYC-A1 2 PYC-P z 4 Applicable Hold-down Clips z z 3 PT11(QN) PT11-0 z z Y92H-3 z PYC-1 Mounting Height with Sockets Front-mounting Sockets Back-mounting Sockets Note: 1. The PTF@A can be mounted on a track or with screws. 2. The measurements in parentheses are for the LY@-CR (built-in CR circuit). 12 LY Socket Mounting Plates (t = 1.6) Type OMRON can provide Socket Mounting Plate for convenient Socket installation. Please use these Plates as required. Number of sockets 1 10 12 18 PT08 PT08QN PYP-1 --- --- PYP-18 PT11 PT11QN PTP-1-3 --- PTP-12 --- PT14 PT14QN PTP-1 PTP-10 --- --- Sockets PYP-1 PTP-1-3 PTP-1 49 42±0.1 Two, 3.4-dia. holes PYP-18 R5 59 Four, 3.4-dia. holes 7.7 21.6 7.7 492 17×27.4 = 465.8±0.6 13.1 4.5 5.1 42 42±0.1 49 49 3.4 42±0.1 49 5.1 42±0.1 49 52±0.1 28 R5 72, oval holes R1.7 Four, 3.4-dia. holes 21.6 17×27.4 = 465.8±0.6 17×27.4 = 465.8±0.6 PTP-10 PTP-12 7.4 40, oval holes 9×49.4 = 444.6±0.6 13 11×39.4 = 433.4±0.6 48, oval holes 7.7 7.7 42±0.1 49 42±0.1 49 R1.7 1.1 3.4 4.5 9×49.4 = 444.6±0.6 9×49.4 = 444.6±0.6 3.4 7.4 23.7 492 R2.25 4.5 11×39.4 = 433.4±0.6 11×39.4 = 433.4±0.6 12, square holes 29.3 492 Safety Precautions Refer to the Common Relay Precautions for precautions that apply to all Relays. Precautions for Correct Use • Use two M3 screws to attach case-surface-mounted models (LY1F, LY2F, LY3F, and LY4F) and tighten the screws securely. (Normal tightening torque: 0.98 N·m) • For Relays with Tab Terminals, select a wire diameter for the lead wires that connect to the faston receptacle terminals that is within the allowed range for the load current. • Do not impose excessive external force on the Relay when inserting the Relay to the faston receptacle or pulling the Relay out from the faston receptacle. Do not attempt to insert a terminal diagonally or insert or pull out more than one terminal at the same time. • LY Single-contact Relays are for power switching applications. Do not use the LY Series for switching minute loads of 100 mA or less, such as signals. About the Built-in Diode and CR Elements The diode or CR element that are built into the Relay are designed to absorb the reverse voltage from the Relay coil. If a large surge in voltage is applied to the diode or CR element from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. Applying 10 A or More When Using an LY Relay with the Following Sockets When you use an LY-series relay in combination with the PTF08A, PTF08A-E, or PT08, connect each of the following terminal pairs: (1) to (2), (3) to (4), and (5) to (6). Relay Replacement To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. Attaching and Removing Relay Hold-down Clips When you attach a Hold-down Clip to or remove it from a Socket, wear gloves or take other measures to prevent injuring your fingers on the Hold-down Clip. 13 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.
DEL-LY4F- DC24 价格&库存

很抱歉,暂时无法提供与“DEL-LY4F- DC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货